0 CAD 0.00
items in your cartto quote Checkout
Ooops no items were found.
Try something else.
Ok
Loading…

Crosstex ConFirm 10 Hour Digital Incubator Kit

Crosstex ConFirm 10 Hour Digital Incubator Kit = 900-C10SK

Crosstex ConFirm 10 Hour Digital Incubator Kit

1 In Stock
Item Code: 900-C10SK
Manufacturer Surgo Surgical Supply
Manufacturer Ref C10SK

Description

ConFirm 10, the first spore testing system that delivers results in just 10 hours.

Details

  • In-office biological monitoring system provides final results in just 10 hours
  • Simply process test indicator vial in a normal steam sterilization cycle, remove, crush ampoule and place in incubator along with an unprocessed control vial for required 10 hour incubation period
  • Media in test vial will turn yellow if any spores remain alive, thus signifying a failed test
  • If the test fails, immediately retest to determine if sterilizer is not functioning properly or if it was human error (most common reason for test failure)
  • If second test fails, remove sterilizer from service immediately and contact your local equipment service provider
  • Easy-to-read
  • Easy-to-use

Contents

  • Incubator
  • Record Keeper Booklit>
  • Manual

Specifications

Made In

US

Catalog Page Number

105

Brand

Surgo Surgical Supply

Category

Confirm 10 Hour Biological Monitoring

Starting from
CAD 802.50 / EA
/
1
LIST PRICE CAD 930.00
14%
- +
Compare

Crosstex ConFirm 10 Hour Digital Incubator Kit

Crosstex ConFirm 10 Hour Digital Incubator Kit = 900-C10SK

Crosstex ConFirm 10 Hour Digital Incubator Kit

1 In Stock
Item Code: 900-C10SK
Manufacturer Surgo Surgical Supply
Manufacturer Ref C10SK
Starting from
CAD 802.50 / EA
/
1
LIST PRICE CAD 930.00
14%
- +
Compare

Description

ConFirm 10, the first spore testing system that delivers results in just 10 hours.

Details

  • In-office biological monitoring system provides final results in just 10 hours
  • Simply process test indicator vial in a normal steam sterilization cycle, remove, crush ampoule and place in incubator along with an unprocessed control vial for required 10 hour incubation period
  • Media in test vial will turn yellow if any spores remain alive, thus signifying a failed test
  • If the test fails, immediately retest to determine if sterilizer is not functioning properly or if it was human error (most common reason for test failure)
  • If second test fails, remove sterilizer from service immediately and contact your local equipment service provider
  • Easy-to-read
  • Easy-to-use

Contents

  • Incubator
  • Record Keeper Booklit>
  • Manual

Specifications

Made In

US

Catalog Page Number

105

Brand

Surgo Surgical Supply

Category

Confirm 10 Hour Biological Monitoring

SEARCH ×