0 CAD 0.00
items in your cartto quote Checkout
Ooops no items were found.
Try something else.
Ok
Loading…

SAM Pelvic Sling II - 19 x 15 x 10cm

SAM Pelvic Sling II - 19 x 15 x 10cm = 850-57703X SAM Pelvic Sling II - 19 x 15 x 10cm = 850-57703X
SAM Pelvic Sling II - 19 x 15 x 10cm = 850-57703X SAM Pelvic Sling II - 19 x 15 x 10cm = 850-57703X

SAM Pelvic Sling II - 19 x 15 x 10cm

More coming soon
Item Code: 850-57703X
Manufacturer Ref 57703X

Description

The SAM Pelvic Sling II was designed not to over-tighten or under-tighten, unlike other commercial binders which allow unlimited force to be applied to the patient. Researchers at Legacy Health System utilized cadaver studies and clinical trials to determine the optimum range of force required to safely and effectively close an unstable pelvic fracture.

FOR STABILIZATION OF PELVIC FRACTURES WITH THE CORRECT FORCE

The SAM Pelvic Sling II’s patented Autostop buckle is programmed to stop your pull once the correct compression force has been obtained. This is vital in high stress environments where over-tightening by emergency medical personnel under duress could potentially be extreme and harmful.

Trauma surgeons around the world recognize the importance of stabilizing pelvic fractures during the critical first “golden hour” following severe trauma. Because of the potentially devastating hemorrhage associated with such fractures, standard first aid protocol includes applying some type of circumferential binder around the victim’s hips.

NEWLY IMPROVED ONE PIECE DESIGN

The SAM Pelvic Sling II improves upon our groundbreaking original pelvic sling. It is still the only force-controlled circumferential pelvic belt scientifically proven in peer-reviewed studies to safely and effectively reduce and stabilize open-book pelvic ring fractures.

The SAM Pelvic Sling II is an improved, simpler design with no detachable hardware. It is more compact, easy to use (only three steps) and quick to apply (usually in less than one minute). The standard size fits (without cutting or trimming) 98% of the adult population. It does not require a fine touch to operate and gives clear feedback by sound and feel to confirm correct application.

The sling is durable i.e. not affected by extremes of moisture, temperature or by exposure to hard or sharp objects. It is also radiolucent, MRI safe and cleans for re-use with common detergents or anti-microbial solutions. 

IMPORTANT WARNING

Based on in vitro testing, the SAM Pelvic Sling™ II will not present a hazard or risk to a patient undergoing an MRI procedure using an MR system operating at 3-Tesla or less. The SAM Pelvic Sling™ II contains ferromagnetic springs in the buckle. Therefore, it is important to ensure that the SAM Pelvic Sling™ II is firmly applied to the patient prior to entry into the MRI environment (as stated in the labeling for this device). Accordingly, there will be no hazard or risk to a patient undergoing an MRI procedure. The SAM Pelvic Sling™ II should not be removed from the patient while in the MRI system room.

This product is not recommended for use on children.

WHY DOES CONTROLLING CIRCUMFERENTIAL FORCE MATTER IN THE TREATMENT OF PELVIC FRACTURES?

At the time of initial evaluation, the exact type of fracture is usually unknown. In some cases, too little force will not close or stabilize the fracture; in others, too much force can collapse the pelvic ring. The SAM Pelvic Sling II stands alone as the only pelvic binder pre-programmed to apply the safe and correct force for all pelvic fractures.

BENEFITS AND FEATURES

  • Scientifically and clinically proven to provide safe and effective force to stabilize pelvic fractures
  • Buckle maintains correct force– cannot be over-tightened
  • Standard size fits 98% of population
  • "Click" provides clear feedback to confirm correct application
  • Pulling gradually and symmetrically increases sling tension and reduces the pelvis
  • Low friction posterior slider facilitates transfers
  • Front of Sling is narrow and tapered to facilitate urinary catheterization, interventional radiology, external fixation and abdominal surgery
  • Fabric does not stretch and cleans for reuse with standard detergents or antimicrobial solutions
  • Radiolucent (allowing for X-rays without removal)
  • Ease of application: just insert belt through buckle, pull strap, and secure
  • Velcro on strap and sling for quick and easy fastening
  • Reusable, not a one-time use device
  • Every sling is tested for quality

Specifications

Brand

Sands Canada

Starting from
CAD 260.36 / EA
/
1
LIST PRICE CAD 301.73
14%
- +
Compare

SAM Pelvic Sling II - 19 x 15 x 10cm

SAM Pelvic Sling II - 19 x 15 x 10cm = 850-57703X SAM Pelvic Sling II - 19 x 15 x 10cm = 850-57703X
SAM Pelvic Sling II - 19 x 15 x 10cm = 850-57703X SAM Pelvic Sling II - 19 x 15 x 10cm = 850-57703X

SAM Pelvic Sling II - 19 x 15 x 10cm

More coming soon
Item Code: 850-57703X
Manufacturer Ref 57703X
Starting from
CAD 260.36 / EA
/
1
LIST PRICE CAD 301.73
14%
- +
Compare

Description

The SAM Pelvic Sling II was designed not to over-tighten or under-tighten, unlike other commercial binders which allow unlimited force to be applied to the patient. Researchers at Legacy Health System utilized cadaver studies and clinical trials to determine the optimum range of force required to safely and effectively close an unstable pelvic fracture.

FOR STABILIZATION OF PELVIC FRACTURES WITH THE CORRECT FORCE

The SAM Pelvic Sling II’s patented Autostop buckle is programmed to stop your pull once the correct compression force has been obtained. This is vital in high stress environments where over-tightening by emergency medical personnel under duress could potentially be extreme and harmful.

Trauma surgeons around the world recognize the importance of stabilizing pelvic fractures during the critical first “golden hour” following severe trauma. Because of the potentially devastating hemorrhage associated with such fractures, standard first aid protocol includes applying some type of circumferential binder around the victim’s hips.

NEWLY IMPROVED ONE PIECE DESIGN

The SAM Pelvic Sling II improves upon our groundbreaking original pelvic sling. It is still the only force-controlled circumferential pelvic belt scientifically proven in peer-reviewed studies to safely and effectively reduce and stabilize open-book pelvic ring fractures.

The SAM Pelvic Sling II is an improved, simpler design with no detachable hardware. It is more compact, easy to use (only three steps) and quick to apply (usually in less than one minute). The standard size fits (without cutting or trimming) 98% of the adult population. It does not require a fine touch to operate and gives clear feedback by sound and feel to confirm correct application.

The sling is durable i.e. not affected by extremes of moisture, temperature or by exposure to hard or sharp objects. It is also radiolucent, MRI safe and cleans for re-use with common detergents or anti-microbial solutions. 

IMPORTANT WARNING

Based on in vitro testing, the SAM Pelvic Sling™ II will not present a hazard or risk to a patient undergoing an MRI procedure using an MR system operating at 3-Tesla or less. The SAM Pelvic Sling™ II contains ferromagnetic springs in the buckle. Therefore, it is important to ensure that the SAM Pelvic Sling™ II is firmly applied to the patient prior to entry into the MRI environment (as stated in the labeling for this device). Accordingly, there will be no hazard or risk to a patient undergoing an MRI procedure. The SAM Pelvic Sling™ II should not be removed from the patient while in the MRI system room.

This product is not recommended for use on children.

WHY DOES CONTROLLING CIRCUMFERENTIAL FORCE MATTER IN THE TREATMENT OF PELVIC FRACTURES?

At the time of initial evaluation, the exact type of fracture is usually unknown. In some cases, too little force will not close or stabilize the fracture; in others, too much force can collapse the pelvic ring. The SAM Pelvic Sling II stands alone as the only pelvic binder pre-programmed to apply the safe and correct force for all pelvic fractures.

BENEFITS AND FEATURES

  • Scientifically and clinically proven to provide safe and effective force to stabilize pelvic fractures
  • Buckle maintains correct force– cannot be over-tightened
  • Standard size fits 98% of population
  • "Click" provides clear feedback to confirm correct application
  • Pulling gradually and symmetrically increases sling tension and reduces the pelvis
  • Low friction posterior slider facilitates transfers
  • Front of Sling is narrow and tapered to facilitate urinary catheterization, interventional radiology, external fixation and abdominal surgery
  • Fabric does not stretch and cleans for reuse with standard detergents or antimicrobial solutions
  • Radiolucent (allowing for X-rays without removal)
  • Ease of application: just insert belt through buckle, pull strap, and secure
  • Velcro on strap and sling for quick and easy fastening
  • Reusable, not a one-time use device
  • Every sling is tested for quality

Specifications

Brand

Sands Canada

SEARCH ×